Fluke 3210-PR-TF-II Thin Flex Current Probe
Fluke 3210-PR-TF-II Thin Flex Current Probe
The 3210-PR-TF-II Flex Thin Flex Current Probe (the Probe or Product) is an ac current probe utilizing the Rogowski principle. The Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors.
 Operating Instructions
Connect the Probe to the 1750 via the 1750 current input jack.
Wear protective equipment or de-energize the circuit and place the Probe around the conductor under test.
Re-energize the circuit.
Observe and take measurements as required. Positive output indicates that the current flow is in the direction shown by the arrow on the Probe.
Wear protective equipment or de-energize the circuit before removal of the Probe.
 Maintenance
Clean the Probe periodically by wiping it with a damp cloth and detergent. Do not use abrasive cleaners or solvents. Do not immerse the Probe in liquids.
Specifications
Electrical CharacteristicsÂ
Measurement Range : 20 to 1000 A (with a crest factor ?3)Â
Frequency Range : 40 Hz to 5 kHzÂ
Accuracy (@ 25 °C) : ±1 % of readingÂ
Linearity (10 % to 100 % of range) : ±0.2 % of readingÂ
Temperature Coefficient : ±0.05 % of reading per °CÂ
Position Sensitivity (with cable >25 mm from the coupling) : ±2 % of readingÂ
External Field (with cable >200 mm from the head) : ±1 % of readingÂ
Working Voltage (see Safety Standards) 1000 V ac rms or dc
 Â
General CharacteristicsÂ
Probe Cable Length : 24 in. (610 mm)
Probe Cable Diameter : 0.3 in. (8 mm)
Transducer Bend Radius (min) : 1.5 in. (38.1 mm)
Output Cable : 2 core screened, double insulated, 3 meters long
Output Connector LEMO : 6 pin male connector
Operating Temperature Range : -4 to +158 °F (-20 to +70 °C) (the temperature of the conductor under test shall not exceed 176 °F /80 °C)
Storage Temperature Range : -40 to 176 °F (-40 to +80 °C)
Operating Humidity : 15 % to 85 % (non condensing)
Altitude : max 6562 ft. (2000 m)
Degree of ingress protection : IP40 (IEC 60529)